AX-754-K787
Enclosed AC/DC power supply
Power102 W
Output voltage12 V
Current8.5 A
ARMSENS
Technical specifications
| Manufacturer Part Number (MPN) | AX-754-K787 |
|---|---|
| Manufacturer | ARMSENS |
| Output channels | 12 V / 8.5 A |
| Power | 102 W |
| Input voltage | 85–264 VAC / 120–373 VDC |
| Input frequency | 47–63 Hz |
| Dimensions, document order | 129 × 97 × 30 mm |
| Output voltage | 12 V |
| Current | 8.5 A |
| Ripple and noise | 120 mVp-p |
| Output voltage adjustment | ±10% |
| Output voltage tolerance | ±1.0% |
| Line regulation | ±0.5% |
| Load regulation | ±0.5% |
| Start / rise / hold timing as specified | 500 ms / 30 ms @ 230 VAC; 500 ms / 30 ms @ 115 VAC, full load |
| Hold-up time | 55 ms @ 230 VAC; 10 ms @ 115 VAC, full load |
| Typical efficiency, rated load | 88% @ 230 VAC / 25 °C |
| Input current | 1.9 A @ 115 VAC; 1.2 A @ 230 VAC |
| Inrush current | Cold start: 50 A @ 230 VAC |
| Leakage current | <1 mA @ 240 VAC |
| Short-circuit response | Output shuts down when +VO reaches the undervoltage point |
| Operating temperature / humidity | −30…+70 °C; 20–90% RH |
| Storage temperature / humidity | −40…+85 °C; 10–95% RH |
| Dielectric withstand | Input–output: 4 kVAC; input–case: 2 kVAC; output–case: 1.25 kVAC; 1 minute |
| Net / gross mass | 340 / 365 g |
| Ripple measurement conditions | 20 MHz bandwidth; 0.1 µF and 47 µF capacitors in parallel at the output terminals |
| Series | AX-754 |
| Product type | Enclosed AC/DC power supply |
Product overview
AX-754-K787 is part of the AX-754 enclosed AC/DC power supply family. Rated output configuration: 12 V / 8.5 A; 102 W. The supply accepts 85–264 VAC / 120–373 VDC. The specified input frequency is 47–63 Hz. The assembly uses a ventilated metal enclosure. Heat is dissipated without a fan. Additional electrical data for this variant: ripple and noise 120 mVp-p, output adjustment ±10%, typical efficiency 88% @ 230 VAC / 25 °C. Allow for a body measuring 129 × 97 × 30 mm, in the dimension order used by the technical document. Match each output to its load and review the available installation information below.
Documents & drawings